Vue de la page 19
20 Data link
terminals on the main circuit board, or across the corresponding terminals
on the connection block (at position D).
If you terminate the data link internally then you will need to change the
supplied dual cable (with male and female XLR connectors) to a single
cable with a male connector. The process for changing the XLR cable is
very similar to that for changing the power lead (see “Hard wiring the fixture
to power” on page 14). The cable enters the fixture (at position E) and the
leads are connected to the connection block (at position D).
Building a data link
To build a data link:
1. Connect a data cable to the controller’s data output. A male 5-pin to
female 3-pin adaptor may be required. Lead the data cable from the
controller to the first fixture and plug it into the fixture’s male data cable.
2. Connect the output of the fixture closest to the controller to the input of
the next fixture. Continue in this manner. Up to 32 fixtures may be
connected output to input.
3. Terminate the link as described above, at the output of the last fixture in
the chain.
A A
B
C
D
E
MAINS INPUT
(Yellow)
(Blue)
(Red)
(Green)