Martin MiniMAC Maestro Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
16 AC power
13. Install a 6.3 mm (1/4 in.) insulated female spade terminal on the live lead
(brown), and plug the lead into the back of the main fuse holder (B).
14. Replace the printed circuit board (A). Bundle the wires together as
before with zip ties.
15. Verify that both nuts on the cable gland are tight (E). Check the condition
of the seal for the back cover. Replace with a new one (P/N 20600020) if
the seal is torn, cracked or brittle.
16. Insert the Allen screws through all holes in the cover and the seal. Place
the cover firmly against the body. Adjust the straight sides of the seal so
that they stick out a little, just enough so that you can feel the seal when
you run a finger across the joint.
17. Cross-tighten the cover bolts evenly. The correct torque for these bolts is
2 Nm (1.5 ft.-lbs.). At this torque, the seal will be compressed by about
one-third.
The cable gland must be replaced if the outside cable diameter is larger
than 10 mm or smaller than 5.5 mm. See “Cable glands” on page 59.
Installing a plug on the power cable
A non-IP-rated plug may be installed on the power cable for testing, service,
and temporary applications only. For outdoor installations, a power plug
rated IP65 minimum must be used. The following table details some
commonly used wiring configurations.
Wire (EU) Wire (US) Pin Marking Screw (US)
brown black live “L” yellow or
brass
blue white neutral “N” silver
yellow/green green ground green
MAINS INPUT