Martin MiniMAC Maestro Manuel d'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 84
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
18 Data link
Data link
A data link is required for DMX controller operation and for synchronized
stand-alone operation of multiple fixtures.
Cable and junctions
The Exterior 600 is supplied with a dual 3 meter (10 ft.) 24 AWG cable tail
with two IP65-rated locking 3-pin XLR connectors for data connection. The
male connector is for data input and the female connector is for data output.
The connectors are wired pin 1 to shield (ground), pin 2 to signal - (cold),
and pin 3 to signal + (hot).
Use RS-485 data cable designed for outdoor use to extend the link. RS-485
cable has low capacitance and a characteristic impedance of 85 to 150
Ohms. It is electrically shielded and has at least 1 twisted pair of conductors.
The minimum recommended wire size is 0.25 mm
2
(24 AWG) for runs up to
300 meters (1000 ft.) and 0.34 mm
2
(22 AWG) for runs up 500 meters (1640
ft.).
Warning! Connectors on earlier models are not weatherproof, and if these
connectors are exposed to water, moisture can be drawn up the
inside of the cables when temperature fluctuation during
operation causes expansion and contraction.
When installing the Exterior 600 outdoors, use one of the
following measures to ensure that the fixture is protected from
water entry caused by suction inside the data cable:
Protect connectors on the data cable with weatherproof housings
or junction boxes, or
Use waterproof outdoor cable and IP65-rated XLR connectors such
as the NC 3 MX-HD-B and NC 3 FX-HD-B produced by Neutrik that
are supplied with current Exterior 600s.
Vue de la page 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 83 84

Commentaires sur ces manuels

Pas de commentaire