CX-2 user manual Troubleshooting 19
T
ROUBLESHOOTING
10
Problem Probable cause(s) Remedy
One or more of the fixtures is
completely dead.
No power to fixture. Check that power is switched on
and cables are plugged in.
Primary fuse blown. Replace fuse.
Secondary fuse blown. Replace fuse.
Fixtures reset correctly but all
respond erratically or not at all
to the controller.
The controller is not connected. Connect controller.
XLR pin-out of the controller
does not match pin-out of the
first fixture on the link (i.e.
signal is reversed).
Install a phase-reversing cable
between the controller and the
first fixture on the link.
Fixtures reset correctly but
some respond erratically or not
at all to the controller.
Bad data link connection Inspect connections and cables.
Correct poor connections.
Repair or replace damaged
cables.
Data link not terminated with
120Ω termination plug.
Insert termination plug in output
jack of the last fixture on the
link.
Incorrect addressing of the
fixtures.
Check DIP-switch settings.
One of the fixtures is
transmitting as a master or is
defective.
Bypass one fixture at a time
until normal operation is
regained: unplug both
connectors and connect them
directly together. Have the
defective fixture serviced by a
qualified technician.
An effect fails to reset correctly. The effect requires mechanical
adjustment.
Contact Martin technician for
service.
No light. Lamp missing or blown Disconnect fixture and replace
lamp.
Lamp cuts out intermittently or
burns out too quickly.
Fixture is too hot. Allow fixture to cool.
The transformer setting does not
match local AC voltage.
Check AC setting.