12 Stand-alone operation CX-2 user manual
To set the master
Important! Set only 1 fixture as master (DIP-switch pin 2 and 10 ON).
1 Set DIP-switch pins 2 and 10 to ON.
2 Set DIP-switch pins 3, 5, 6, 7, 8, 9, and 11 to OFF.
3 Select options with DIP-switch pins 1, 4, and 12.
To set a slave
1 Set DIP-switch 10 to ON.
2 Set pins 1, 2, 3, 4, 5 and 11 to OFF.
3 Select options with DIP-switch pins 6, 7, 8, 9, and 12.
STAND-ALONE SETTINGS
DIP-switch pins 1-9 enable stand-alone options only when pin 10 is ON. When
pin 10 is off, the DIP-switch selects a DMX address. Pin 11 must be OFF for
stand-alone operation.
Pin 12 selects lamp power and works in all modes. Set it to ON for reduced lamp
voltage and longer lamp life; set it to OFF for full intensity.
The DIP-switch 10 setting takes effect only after the fixture has been turned off
and on.
Fixture Option Setting (0 = OFF, 1 = ON)
1234567891011
single or
master
auto trigger 0 1 0 0
10
music trigger 1 1 0 0
slow change 1 0 1 0
slave
random color 0 1
random gobo 0 1
inverted color 0 1
inverted gobo 0 1
102 3 4 51 86 7 9
ON
1211
102 3 4 51 86 7 9
ON
1211
Commentaires sur ces manuels