Martin MAC 500 Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
Lamp 7
4. With the nipple on the replacement lamp facing towards the back as shown in Figure 3, insert the left pin
into the socket. Push down on the right-hand spring and snap the pin into place.
5. Make sure that the terminals on the lamp sit below the V-section in the lampholder clips and not in the
V-section itself, as shown in Figure 4.
6. Lift the lamp assembly so that lamp is level with the center of the reflector. Push the assembly straight in
until it seats, making sure the lamp passes through the reflector opening.
7. Push and turn the 4 fasteners a quarter turn or so clockwise to close the lamp access panel.
8. After installing a new lamp, reset the lamp hour and lamp strike counters. See “Time” on page 12.
To align the lamp
Important! Align the lamp carefully. An excessive hot-spot
will damage optical components.
1. Switch on the MAC 550 Profile and allow it to reset.
Using either a controller or the control module, turn on
the lamp and project an open white beam on a flat
surface.
2. Center the hot spot vertically using the top Allen-head
adjustment screw in the center of the rear plate. (See
Figure 5.) If there is significant hot spot, turn the bottom
adjustment screw counterclockwise until the light is
evenly distributed. If the light is brighter around the
edge than it is in the center, or if light output is low, turn
the bottom adjustment screw clockwise until the light is
bright and evenly distributed.
Figure 3: Lamp insertion
Nipple facing towards back
Figure 4: Lamp terminals
Figure 5: Lamp adjustment screws
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 41 42

Commentaires sur ces manuels

Pas de commentaire