5Setup
MARTIN MODE SETUP
The converter automatically switches to Martin mode when used with Martin
protocol controllers. You may wish to swap the polarity of the serial data link
connectors as described below so they have the same pin-out as the controller.
XLR pin-out
The converter’s serial data link sockets are factory set to the DMX pin-out. For
use with Martin protocol controllers, you can either switch the pin-out or use a
phase-reversing cable between the controller and the converter.
1 Disconnect the converter from power. Remove the top cover, which is
secured by 1 screw on each end and 3 screws on the back.
2 Locate the jumpers at PL112 on the small circuit board.
3 Position the jumpers as shown below for the desired pin-out.
4 Replace the top cover before applying power.
AC power
Warning! For protection from electric shock, the converter must be
grounded (earthed). The AC mains supply shall have overload
and ground-fault protection.
CHECK VOLTAGE SETTING
Before use verify that the converter’s power supply is correctly set for the local
AC voltage.
Locate the 115/230 V selector switch on the back. Select the voltage that most
closely matches your AC supply.
INSTALL A PLUG ON THE MAINS LEAD
The converter’s mains lead must be fitted with a grounding-type cord cap that fits
your power distribution cable or outlet. Consult a qualified electrician if you have
any doubts about proper installation.
2
3
+
-
2
3
+
-
DMX pin-outMartin pin-out