Martin P3 PowerPort 1500 Manuel d'utilisateur Page 17

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 16
Using the VC-Grid 17
LED status feedback
The VC-Grid gives status information via its LEDs as shown in Table 2:
To display status, press the control button once. Four LEDs will give one of the indications listed in Table 2
for a few seconds.
Color Output Indication Action required
Blue Constant
Busy (e.g. booting up or writing to
flash memory).
Wait a moment for normal operation
to be resumed.
Red Constant
Error. The VC-Grid has encountered
a fatal error and can not run.
Perform a factory reboot, followed by
a firmware upload.
Red Flashing No control source detected.
Connect a P3 system controller or
DMX source to the network.
Green Flashing
Ready. VC-Grid connected to P3
controller but not receiving valid P3
data stream.
Set up the P3 controller to use the
products connected to the VC-Grid.
Green Constant Running normally in P3 mode. None.
Cyan Flashing
Ready. VC-Grid connected to DMX
controller but not receiving valid
DMX data stream.
Set up the DMX controller to use the
products connected to the VC-Grid.
Cyan Constant Running normally in DMX mode. None.
Table 2: Key to LED status information